What works

Default install and basic operation.

What does not

Custom install. Selecting individual components causes hang. (minor problem)

View>Options>Current>View Changes: Does not retain Fast Zoom or IntelliMouse Zoom Percentage values (minor problem)

Numeric values in dialogs, dimensions, and exported drawings always have engineering display format, i.e., 1..0000000000000e+ instead of 1. (major problem)

Workarounds

What was not tested

Printing.

Hardware tested

Graphics:

  • GPU:
  • Driver:

Additional Comments

Tested version 7.0 Build 54 Can't find shared DLLs unless started in folder containing them. Required command line: cd ~/.wine/drive_c/"Program Files"/"Common Files"/"Autodesk Shared"; wine ../../AutoSketch/Sketch.exe

selected in Test Results table below
Operating systemTest dateWine versionInstalls?Runs?Used
Workaround?
RatingSubmitter
ShowUbuntu 14.04 "Trusty" amd64 (+ variants like Kubuntu)Jan 04 20161.8Yes Yes NoSilverJeff D. Hanson 
ShowUbuntu 14.04 "Trusty" amd64 (+ variants like Kubuntu)Jan 01 20151.7.33Yes Yes NoSilverJeff D. Hanson 
ShowUbuntu 8.04 "Hardy" amd64 (+ variants like Kubuntu)Apr 20 20091.1.19Yes Yes NoGoldJeff D. Hanson 
ShowUbuntu 10.04 "Lucid" amd64 (+ variants like Kubuntu)Jul 11 20101.0.1Yes Yes NoGoldan anonymous user 
ShowUbuntu 7.10 "Gutsy" i386 (+ variants like Kubuntu)Apr 15 20080.9.59.Yes Yes NoGoldJeff D. Hanson 

Known Bugs

Bug # Description Status Resolution Other apps affected

Show all bugs

HowTo / Notes

Installation note

AutoSketch 7 will not execute after installation because it is not able to find the directory containing some of its dependencies.  To manually fix it, run regedit and navigate to:

HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Session Manager\Environment

Look for the PATH value.  Edit it and add a semicolon (;) at the end followed by:

c:\Program Files\Common Files\Autodesk Shared

Close regedit.  AutoSketch should now start normally.

Technical Information
Uses AnswerWorks (WexTech Systems) and Novell Morphological Speller (Novell, Lernout & Hauspie).