This is a software oscilloscope application for the Velleman PCSGU250 USB Oscilloscope.
Application Details:
Version: | 1.01 |
License: | Retail |
URL: | http://www.vellemanusa.com/us/... |
Votes: | 0 |
Latest Rating: | Garbage |
Latest Wine Version Tested: | 6.0.3-staging |
Maintainers: About Maintainership
No maintainers. Volunteer today!
What works
The software installs without error.
What does not
Running the application leads to two error messages;
1) Access violation at address 004C8EAA in module 'Pc:ab2000LT.exe'. Read of address 00000044.
2) Invalid floating point operation.
There is no oscilloscope trace. An attempt to "calibrate & exit" from File menu results in a "No hardware response!" error message, which suggests modifyin the settings in Options|Hardware setup. This option only allows selection between PCSGU250 and Demo mode. Choosing either sets the application into Demo mode.
Workarounds
What was not tested
Most everything.
Hardware tested
Graphics:
Additional Comments
This is likely an USB access problem. Is there any WIne magic that can wrap a Linux USB port to make it look like a Windows USB port?
Operating system | Test date | Wine version | Installs? | Runs? | Used Workaround? | Rating | Submitter | ||
Current | Fedora 34 x86_64 | Mar 11 2022 | 6.0.3-staging | Yes | No | No | Garbage | Cliff Wheatley |
Bug # | Description | Status | Resolution | Other apps affected |
Comments for this application have been disabled because there are no maintainers.